Commands - 101
PULSE
Process Function
SYNTAX: n= PULSE(m)
PURPOSE: To return the r emaining time of a pulsed output.
REMARK S: The resolution of the software pulse timers is 0.005 seconds (0.01 sec in 9 Mhz systems). The
remaining time is returned in seconds. A time of 0 indicates the PULSE comm and finished.
The argument range for m is 0 to 7, which is the pulse number set by the PULSE command.
See the Multitasking Chapter for more information.
RELATED: CLEAR PU LSE, PULSE command
EXAMPLE: 10 A=PULSE(2)
ERROR: < Data negative> for m